The display unit may not be in contact with the mounting bracket. Push the display unit firmly onto the mounting bracket until a loud ‘click’ is heard.
The seat magnet may not be passing close enough to the stroke rate sensor. Make sure that the magnet is passing directly over the black sensor and within 3/4".
The magnet and stroke rate sensor may not be correctly aligned. Make sure that the magnet and black sensor are both across (perpendicular to) the long axis of the boat.
If possible, swap your control unit with a control unit you know works. If the stroke rate begins working, your problem lies with your control unit. If the stroke rate still does not work, your problem lies with your mounting bracket, stroke rate sensor or magnet.
|